North America / English Change

 

Flow-Mate
Model 95

PREMIUM SERIES submersible pump for dewatering (sump) systems

 
 
Features andBenefits
ProductSpecifications
TechnicalData
Literature and Documents

  • 5-year warranty
  • Corrosion-resistant, powder coated epoxy finish
  • Durable, cast iron construction
  • Cast iron switch case, motor, pump housing and base
  • Viton outer switch boot
  • No sheet metal parts to rust or corrode
  • All castings are cast iron class 25-30 25000# tensile strength
  • Stainless steel screws, guard, handle, arm and seal assembly
  • Float-operated, submersible, 2-pole mechanical switch integrating advanced switch technology
  • Permanent split capacitor motor, oil-filled and hermetically-sealed, automatic reset thermal overload protection
  • Bearings – upper and lower oil-fed cast iron
  • Carbon and ceramic shaft seal
  • Entire unit pressure-tested after assembly
  • Watertight, neoprene square ring between motor and pump housing
  • Maximum temperature for effluent or dewatering: 130 °F (54 °C)
  • Passes 1/2” (12 mm) spherical solids
  • No screens to clog
  • 1-1/2” NPT discharge (1-1/2” x 2” PVC adapter included with BN and BE Models)
  • On point: 9-1/2” (24 cm)
  • Off point: 3” (8 cm)
  • Major width: 10-1/8" (31 cm)
  • Major height: 12-1/8" (30 cm)
  • Simplex and duplex systems available

Consult Factory for Special Applications

  • Electrical alternators for duplex systems are available and supplied with an alarm
  • Mechanical alternators for duplex systems are available with or without alarm switches
  • Variable level float switches are available for controlling single and three phase systems
  • Refer to FM1922 and FM0806 for temperatures above 130 °F (54 °C)
Notes

The sizing of effluent systems normally requires variable level float(s) controls and properly sized basins to achieve required pumping cycles or dosing timers with non-automatic pumps.

Reserve Powered Design.
For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.

HERTZ
60 Hz
MOTOR
1/2
VOLTAGE
115
PHASE
1 Ph
RPM
3450
TYPE
Permanent split capacitor
INSULATION
Class B
AMPS
10.5
OPERATION
Automatic
AUTO ON/ OFF POINTS
9-1/2" (24 cm) / 2-1/2" (6.4 cm)
DISCHARGE SIZE
1-1/2" NPT
SOLIDS HANDLING
1/2" (12 mm) spherical solids
CORD LENGTH
15' (4.6 m)
CORD TYPE
UL listed, 3-wire, grounded plug
MAX HEAD
26' (7.9 m)
MAX FLOW RATE
80 GPM (303 LPM)
MAX OPERATING TEMP
130° F (54° C)
COOLING
Oil filled
MOTOR PROTECTION
Auto reset thermal overload
CAP
Cast iron
MOTOR HOUSING
Cast iron
PUMP HOUSING
Cast iron
BASE
Cast iron
UPPER BEARING
Sleeve bearing
LOWER BEARING
Ball bearing
MECHANICAL SEALS
Carbon and ceramic
IMPELLER TYPE
Non-clogging vortex
IMPELLER
Engineered thermoplastic
HARDWARE
Stainless steel
MOTOR SHAFT
AISI 1215 cold rolled steel
GASKET
Neoprene

  • 54
  • 2
  • 8
  • 11

Model Comparison Charts

Performance Curves

Dimensional Data Drawings

Caution

All installation of controls, protection devices and wiring should be done by a qualified licensed electrician. All electrical and safety codes should be followed including the most recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).

Selection Guide

  1. Integral float operated mechanical switch, no external control required.
  2. For automatic use, single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477.
  3. See FM1228 for correct model of simplex control panel.
  4. See FM0712 for correct model of duplex control panel.
  5. To select an appropriate basin, go to Basins.

Optional Pump Stand P/N 10-2421

Accessories

×

 

 

×